Article 225 of the National Electrical Code (NEC) covers requirements for outdoor branch circuits and feeders. These circuits and feeders are used to power outdoor lighting, irrigation systems, and other outdoor equipment. Compliance with Article 225 is essential to ensure that outdoor electrical installations are safe, reliable, and meet the highest standards of electrical safety.

Section 225.3 Clearances

This section covers the clearance requirements for outdoor branch circuits and feeders. The NEC specifies the minimum distance that must be maintained between outdoor electrical equipment and nearby objects such as buildings, trees, and other structures. Compliance with these clearance requirements is essential to prevent contact between electrical equipment and objects that could cause damage or pose a safety hazard.

Section 225.6 Grounding

This section covers the grounding requirements for outdoor branch circuits and feeders. The NEC requires that all outdoor electrical equipment be grounded to prevent the buildup of static electricity and to protect against electrical shock. Compliance with these grounding requirements is essential to ensure that outdoor electrical installations are safe and reliable.

Section 225.10 Outside Branch Circuits and Feeders

This section covers the requirements for outside branch circuits and feeders. The NEC specifies the type of wiring that must be used for outside branch circuits and feeders, as well as the ampacity and size of conductors required for these circuits. Compliance with these requirements is essential to ensure that outside branch circuits and feeders are capable of delivering the necessary electrical power to outdoor equipment.

Section 225.12 Location of Disconnecting Means

This section covers the location of disconnecting means for outside branch circuits and feeders. The NEC requires that disconnecting means be located at a readily accessible location, usually within sight of the outdoor equipment being served. Compliance with these requirements is essential to ensure that outdoor electrical equipment can be easily shut down in the event of an emergency.

Section 225.20 Installation of Outdoor Overhead Conductors and Cables

This section covers the installation of outdoor overhead conductors and cables. The NEC specifies the minimum clearance requirements for overhead conductors and cables, as well as the maximum allowable sag for overhead conductors. Compliance with these requirements is essential to ensure that overhead conductors and cables are installed safely and securely.

Section 225.24 Installation of Underground Feeder and Branch-Circuit Cables

This section covers the installation of underground feeder and branch-circuit cables. The NEC specifies the minimum depth requirements for underground cables, as well as the type of conduit that must be used to protect these cables. Compliance with these requirements is essential to ensure that underground feeder and branch-circuit cables are protected from damage and can deliver the necessary electrical power to outdoor equipment.

Section 225.26 Disconnecting Means for Underground Feeder and Branch-Circuit Cables

This section covers the requirements for disconnecting means for underground feeder and branch-circuit cables. The NEC requires that disconnecting means be located at a readily accessible location, usually within sight of the outdoor equipment being served. Compliance with these requirements is essential to ensure that underground electrical equipment can be easily shut down in the event of an emergency.

In conclusion, compliance with Article 225 of the National Electrical Code is essential to ensure that outdoor electrical installations are safe, reliable, and meet the highest standards of electrical safety. Compliance with the NEC is essential to ensure that electrical installations are safe, reliable, and meet the highest standards of electrical safety. Electrical estimators must have a thorough understanding of Article 225 to ensure compliance with the NEC and provide accurate estimates for outdoor electrical installations. Compliance with the NEC is essential to ensure that outdoor electrical installations are safe, reliable, and meet the highest standards of electrical safety.